Jump to content

Tektronix 2232: Difference between revisions

From Photonicamp Wiki
Created blank page
 
No edit summary
Line 1: Line 1:
'''Tektronix 2232 Oscilloscope Summary'''


The Tektronix 2232 is a dual-channel, 100 MHz bandwidth oscilloscope that combines analog and digital storage capabilities. It features a dual time base and offers a range of functionalities suitable for various electronic testing applications.
<span id="key-features"></span>
== Key Features ==
* '''Bandwidth''': 100 MHz (both analog and digital storage modes)
* '''Sampling Rate''': 100 MS/s digital sampling rate
* '''Glitch Capture''': 10 ns glitch capture at any sweep speed
* '''Record Length''': Selectable 1K or 4K record length
* '''Memory''': 26K extended memory for storing up to 26 waveform sets
* '''Triggering''': Various trigger modes including internal, external, and TV line/field triggers
* '''Vertical System''': 2 mV/div to 5 V/div deflection factor with ±2% accuracy (15°C to 35°C) and ±3% accuracy (0°C to 50°C)
* '''Input Characteristics''': 1 Megohm input resistance, 20 pF input capacitance, and a maximum input voltage of 400 V (DC + peak AC)
* '''Channel Isolation''': 100:1 at 50 MHz
* '''Communication Options''': GPIB or RS-232C interfaces
* '''Physical Characteristics''': 8.2 kg weight, 137 mm height, 360 mm width (with handle), and 440 mm depth (without front cover)
<span id="operational-modes"></span>
== Operational Modes ==
* '''Vertical Operating Modes''': CH1, CH2, CH2 INVERT, ADD, ALT, CHOP (500 kHz), and XY
* '''Trigger Operating Modes''': A-Mode (P-P AUTO, NORM, TV LINE, TV FIELD, SGL SWP) and B-Mode (Runs-After-Delay, Triggered-After-Delay)
* '''X-Y Operation''': Up to 100 MHz bandwidth in store mode, with ±3 degrees phase difference from DC to 150 kHz
<span id="additional-features"></span>
== Additional Features ==
* '''Cursor Function''': DeltaVolts and DeltaTime measurements with ±3% accuracy
* '''X-Y Plotter Output''': Plots displayed waveforms, CRT readout, and graticule
* '''External Clock Input''': Supports DC to 1 kHz in roll mode and DC to 100 kHz in record mode
<span id="safety-and-compliance"></span>
== Safety and Compliance ==
* '''Safety Certifications''': UL listed 1244, Certified to CSA C22.2 No. 231-M39
* '''Environmental Testing''': Withstands 30 g shock, 1/2 sine, 11 ms duration, and operates within specified vibration conditions
<span id="references"></span>
== References ==
# '''Tektronix 2232 Datasheet''' - https://www.tek.com/en/datasheet/2232-digital-and-analog-oscillscope
# '''Tektronix 2232 Manual''' - https://w140.com/tekwiki/images/2/2d/070-7067-00.pdf
# '''TekWiki 2232 Page''' - https://w140.com/tekwiki/wiki/2232
# '''EEVblog Discussion''' - https://www.eevblog.com/forum/testgear/should-i-acquire-a-tektronix-2232/
# '''Tektronix Oscilloscope Overview''' - https://www.tek.com/en/products/oscilloscopes

Revision as of 15:52, 16 December 2024

Tektronix 2232 Oscilloscope Summary

The Tektronix 2232 is a dual-channel, 100 MHz bandwidth oscilloscope that combines analog and digital storage capabilities. It features a dual time base and offers a range of functionalities suitable for various electronic testing applications.

Key Features

  • Bandwidth: 100 MHz (both analog and digital storage modes)
  • Sampling Rate: 100 MS/s digital sampling rate
  • Glitch Capture: 10 ns glitch capture at any sweep speed
  • Record Length: Selectable 1K or 4K record length
  • Memory: 26K extended memory for storing up to 26 waveform sets
  • Triggering: Various trigger modes including internal, external, and TV line/field triggers
  • Vertical System: 2 mV/div to 5 V/div deflection factor with ±2% accuracy (15°C to 35°C) and ±3% accuracy (0°C to 50°C)
  • Input Characteristics: 1 Megohm input resistance, 20 pF input capacitance, and a maximum input voltage of 400 V (DC + peak AC)
  • Channel Isolation: 100:1 at 50 MHz
  • Communication Options: GPIB or RS-232C interfaces
  • Physical Characteristics: 8.2 kg weight, 137 mm height, 360 mm width (with handle), and 440 mm depth (without front cover)

Operational Modes

  • Vertical Operating Modes: CH1, CH2, CH2 INVERT, ADD, ALT, CHOP (500 kHz), and XY
  • Trigger Operating Modes: A-Mode (P-P AUTO, NORM, TV LINE, TV FIELD, SGL SWP) and B-Mode (Runs-After-Delay, Triggered-After-Delay)
  • X-Y Operation: Up to 100 MHz bandwidth in store mode, with ±3 degrees phase difference from DC to 150 kHz

Additional Features

  • Cursor Function: DeltaVolts and DeltaTime measurements with ±3% accuracy
  • X-Y Plotter Output: Plots displayed waveforms, CRT readout, and graticule
  • External Clock Input: Supports DC to 1 kHz in roll mode and DC to 100 kHz in record mode

Safety and Compliance

  • Safety Certifications: UL listed 1244, Certified to CSA C22.2 No. 231-M39
  • Environmental Testing: Withstands 30 g shock, 1/2 sine, 11 ms duration, and operates within specified vibration conditions

References

  1. Tektronix 2232 Datasheet - https://www.tek.com/en/datasheet/2232-digital-and-analog-oscillscope
  2. Tektronix 2232 Manual - https://w140.com/tekwiki/images/2/2d/070-7067-00.pdf
  3. TekWiki 2232 Page - https://w140.com/tekwiki/wiki/2232
  4. EEVblog Discussion - https://www.eevblog.com/forum/testgear/should-i-acquire-a-tektronix-2232/
  5. Tektronix Oscilloscope Overview - https://www.tek.com/en/products/oscilloscopes